Custom Search
Prosthetic-Valve Dehiscence
A 33-year-old man with rheumatic heart disease presented with an acute onset of chest pain. Five years earlier, the patient had undergone replacement of the mitral and aortic valves (Medtronic Hall and ATS Medical, respectively).
On physical examination, he had diaphoresis with normal vital signs and without evidence of congestive heart failure, acute aortic regurgitation, or abnormal prosthetic heart sounds. Electrocardiography that was performed 4 hours after the onset of pain showed ST elevation in left-sided leads V8 and V9, which was suggestive of inferoposterior myocardial injury. Laboratory evaluation revealed an elevated international normalized ratio (>12; normal range, 2.5 to 3.5), a creatine kinase level of 39 U per liter (normal range, 0 to 150), a creatine kinase MB level of 5.5 U per liter (normal range, 0.6 to 6.3), and a troponin I level of 0.24 ng per milliliter (normal range, 0.01 to 0.03).
Cardiac catheterization showed that the prosthetic aortic valve was significantly displaced with each heartbeat (Panels A and B, arrows); no abnormality of the mitral valve was observed. The patient underwent urgent excision and replacement of the dehisced aortic valve, which was found to be infected with Staphylococcus aureus, with associated vasculitis; the mitral valve was not affected. The patient had postoperative mediastinal bleeding and died from irreversible shock 24 hours later.
On physical examination, he had diaphoresis with normal vital signs and without evidence of congestive heart failure, acute aortic regurgitation, or abnormal prosthetic heart sounds. Electrocardiography that was performed 4 hours after the onset of pain showed ST elevation in left-sided leads V8 and V9, which was suggestive of inferoposterior myocardial injury. Laboratory evaluation revealed an elevated international normalized ratio (>12; normal range, 2.5 to 3.5), a creatine kinase level of 39 U per liter (normal range, 0 to 150), a creatine kinase MB level of 5.5 U per liter (normal range, 0.6 to 6.3), and a troponin I level of 0.24 ng per milliliter (normal range, 0.01 to 0.03).
Cardiac catheterization showed that the prosthetic aortic valve was significantly displaced with each heartbeat (Panels A and B, arrows); no abnormality of the mitral valve was observed. The patient underwent urgent excision and replacement of the dehisced aortic valve, which was found to be infected with Staphylococcus aureus, with associated vasculitis; the mitral valve was not affected. The patient had postoperative mediastinal bleeding and died from irreversible shock 24 hours later.
Popular Posts
-
W ind --- pneumonia, atelectasis at 1st 24- 48 hours W ater --- urinary tract infection at Anytime after post op day 3 W ound --- wound ...
-
Raccoon Eyes. Ecchymosis in the periorbital area, resulting from bleeding from a fracture site in the anterior portion of the skull base. Th...
-
Lymph Nodes : The major lymph node groups are located along the anterior and posterior aspects of the neck and on the underside of the jaw. ...
-
Fournier's gangrene is a rare condition and delayed treatment results in fatal outcome. We managed a case of Fournier's gangrene by...
-
Viewed posteriorly the right kidney has its upper edge opposite the 11th dorsal spine and the lower edge of the 11th rib. Its lower edge is ...
-
If you are palpating a swelling like an abdominal swelling infront of the aorta, You have to decide whether the mass you feel is pulsatile/e...
-
The sphenoid bone carries its share of creating part of the base of the cranium. While it can be seen laterally and inferiorly, the shape of...
-
Look at how your jaw ends up when saying first syllable of 'Lateral' or 'Medial' : - "La" : your jaw is now open ...